A dental sterilisation tracking app moves the logbook in your decontamination room onto a phone or tablet. You record the values of each autoclave cycle, the chemical indicator result and the machine’s printout with a photo, and every pouch you prepare is linked to its cycle with a QR label. At an inspection, or when a patient asks, the answer to “which cycle was this instrument sterilised in?” is on record.
The app also reminds you of the jobs that are easy to miss: it sends a notification when a vacuum test or spore test is due and moves pouches past their shelf life onto a “to be resterilised” list. If a cycle’s biological indicator fails, the pouches from that cycle and the patients they were used on are listed on one screen.
Who is it for?
- Dental practices and surgeries: Dentists who want photo-backed, searchable sterilisation records instead of a paper logbook.
- Dental polyclinics: Centres with several autoclaves and washers, where the staff responsible change by shift.
- Surgical and implant practices: Practices that want a record of which surgical kit was used on which patient.
- Dental groups: Quality leads who want to follow every branch’s sterilisation records and test results centrally.
Features that put the decontamination room on record
Autoclave cycle records with photos
For each cycle you enter the machine, cycle number, programme, temperature, pressure and time; you photograph the chemical indicator strip and the machine’s printout or display. Who started the cycle and who approved it are recorded. If the result is marked as a fail, the pouches from that cycle are blocked from use.
Test schedules and missed test alerts
Your practice sets how often the vacuum (Bowie-Dick) test, leak test and biological indicator (spore) test are carried out. When a test is due, a notification goes to the person responsible, and a test that was not done appears as a red alert in the panel the next morning. The spore test’s incubation result is entered later and linked to the cycle.
QR-labelled pouches and shelf life
For each kit or instrument you pack, the app produces a QR-coded label showing the cycle number, packing date, the person who packed it and an expiry date based on the shelf life your practice sets. Pouches past their shelf life move to the “to be resterilised” list and are not used without reprocessing.
Linking pouches to patients and tracing back
When a pouch is opened for treatment, its QR code is scanned and matched with the patient’s name or reference number. If a cycle’s spore test fails, the app lists every pouch from that cycle and, where used, on which day and for which patient, so the practice can decide from this list which patients to contact.
Daily hygiene tasks
Tasks such as dental unit waterline cleaning, surface disinfection, changing the ultrasonic cleaner solution and handing over clinical waste are listed by day and shift. Whoever does a task marks it complete, with their name and the time recorded, and tasks left undone are reported to the dentist in charge.
Plan comparison
| Feature | Starter | Professional | Enterprise |
|---|---|---|---|
| Users | 3 | 8 | 25 |
| Machines (autoclave, washer, thermal disinfector) | 2 | 6 | Unlimited |
| Cycle records with photos and test schedules | ✓ | ✓ | ✓ |
| QR-labelled pouches and shelf life tracking | ✓ | ✓ | ✓ |
| Linking pouches to patients and trace-back lists | — | ✓ | ✓ |
| Daily hygiene tasks | — | ✓ | ✓ |
| Machine maintenance schedule and service records | — | ✓ | ✓ |
| Branches | 1 | 1 | 3 |
| Support | Email / WhatsApp | Email / WhatsApp | Priority |
Starter is enough for surgeries working with one autoclave. Practices that want to link surgical kits to patients and also follow hygiene tasks and machine maintenance choose Professional. Enterprise suits groups that follow the records of several branches centrally.
How do you get started?
- Choose a plan: Pick the plan that matches your users and machines, pay yearly, and your account opens straight away.
- Set up your machines and kits: Enter your autoclaves and washers, kit names and shelf life rules in the panel.
- Set the test frequency: We set up the test and task schedule with you, following your practice’s procedure.
- Record your first cycle: Download the app from the App Store or Google Play, record a cycle with its photo and print the label.
Infrastructure, security and support
The app and web panel run on ADK infrastructure over encrypted connections, and data is backed up every day. Records are never deleted; when a correction is made, the old value, the person who corrected it and the time are kept, so an inspector can see the history of each record. In the panel you can download cycle, test and task reports for any date range as PDFs. Throughout your subscription we provide support by email and WhatsApp.
The sterilisation tracking app is a yearly cloud service. ADK Yazılım publishes the app on the App Store and Google Play; we set up your business account for you, so there is nothing for you to install and no server or domain is needed. Phones, tablets, label printers and labels are not included. The app records your practice’s sterilisation procedure; the practice sets test frequency, shelf life and pass criteria, and the app does not by itself ensure regulatory compliance. Automatic data capture from autoclaves and washers, syncing with practice software and SMS sending are not included and can be added through custom development. Plans are paid yearly; the first-year fee includes account setup, initial configuration, data import from Excel and remote training, and a lower yearly renewal fee applies from the second year.
Entrega rápida
Nuestras bases de producto ya desarrolladas ponen su proyecto en marcha en poco tiempo.
La seguridad, primero
Estándares de programación segura, conexiones cifradas y actualizaciones periódicas.
Soporte continuo
Mantenimiento, actualizaciones y soporte técnico tras el lanzamiento. Seguimos a su lado.